12. Set the following Link IP parameters to complete the MINT network address configuration:
IP
Routing Level
Listening Link
Port
Forced Link
Link Cost
Hello Packet Interval
Adjacency Hold Time
Figure 5-107 Advanced Profile MINT screen - IP tab
Define or override the IP address used by peer access points for
interoperation when supporting the MINT protocol.
Use the spinner control to define or override a routing level of either 1 or 2.
Specify a listening link of either 0 or 1. UDP/IP links can be created by
configuring a matching pair of links, one on each end point. However, that
is error prone and doesn't scale. So UDP/IP links can also listen (in the TCP
sense), and dynamically create connected UDP/IP links when contacted.
To specify a custom port for MiNT links, check this box and use the spinner
control to define or override the port number between 1 and 65,535.
Check this box to specify the MiNT link as a forced link. This setting is
disabled by default.
Use the spinner control to define or override a link cost between 1 - 10,000.
The default value is 100.
Set or override an interval in either Seconds (1 - 120) or Minutes (1 - 2) for
the transmission of hello packets. The default interval is 15 seconds.
Set or override a hold time interval in either Seconds (2 - 600) or Minutes
(1 - 10) for the transmission of hello packets. The default interval is 46
seconds.
Device Configuration 5 - 197