Motorola Solutions WiNG 5.2.6 Reference Manual page 354

Access point
Table of Contents

Advertisement

6 - 92 WiNG 5.2.6 Access Point System Reference Guide
11.Enable or disable
When enabled, detector radios monitor their coverage areas for potential failed peers or coverage area holes
requiring transmission adjustments for coverage compensation.
12.Set the following
Duration
Frequency
Extended Scan
Frequency
Sample Count
Client Aware
Scanning
Power Save Aware
Scanning
Voice Aware
Scanning
13.Select
OK
configuration.
14.Select Recovery. Ensure Activate SMART RF Policy remains selected so the screen's parameters can be updated.
The
Neighbor Recovery
tabs to define how 5 and 2.4 GHz radios compensate for failed neighbor radios, interference and coverage holes
requiring neighbor radio intervention.
Smart Monitoring Enable
Scanning Configurations
Set a channel scan duration (between 20 - 150 milliseconds) access point
radios use to monitor devices within the network and, if necessary, perform
self healing and neighbor recovery to compensate for coverage area losses
within a RF Domain. The default setting is 50 milliseconds for both the 2.4
and 5 GHz bands.
Set the scan frequency using the drop-down menu. Set a scan frequency in
either Seconds (1 - 120) or Minutes (0 - 2). The default setting is 6 seconds
for both the 5 and 2.4 GHz bands.
Use the spinner control to set an extended scan frequency between 0 - 50.
This is the frequency radios scan channels on non-peer radios. The default
setting is 5 for both the 5 and 2.4 GHz bands.
Use the spinner control to set a sample scan count value between 1 - 15.
This is the number of radio RF readings gathered before data is sent to the
Smart RF master. The default setting is 5 for both the 5 and 2.4 GHz bands.
Use the spinner control to set a client awareness count (0 - 255) during off
channel scans for either the 2.4 or 5. GHz radio. The default setting is 0 for
both radio bands.
Select either the Dynamic, Strict or Disable radio button to define how
power save scanning is set for Smart RF. Strict disables smart monitoring
as long as a power save capable client is associated to a radio. Dynamic
disables smart monitoring as long as there is data buffered for a power
save client at the radio. The default setting is Dynamic for both the 5 and
2.4 GHz bands.
Select either the Dynamic, Strict or Disable radio button to define how
voice aware recognition is set for Smart RF. Strict disables smart
monitoring as long as a voice client is associated to a radio. Dynamic
disables smart monitoring as long as there is data buffered for a voice
client at the radio. The default setting is Dynamic for both the 5 and 2.4
GHz bands.
to update the Smart RF Scanning Configuration settings. Select
tab displays by default. Use the Neighbor, Interference and Coverage Hole recovery
by selecting the check box. The feature is enabled by default.
for both the 2.4 and 5 GHz radio bands:
Reset
to revert to the last saved

Hide quick links: