Figure 5-47 Advanced Profile MINT screen - Add IP MiNT Link
8. Set the following Link IP parameters to complete the MINT network address configuration:
IP
Port
Routing Level
Listening Link
Forced Link
Link Cost
Hello Packet Interval
Adjacency Hold Time
Define the IP address used by peer access points for interoperation when
supporting the MINT protocol.
To specify a custom port for MiNT links, select this Port radio button and
use the spinner control to define the port number (1 - 65,535).
Use the spinner control to define a routing level of either 1 or 2.
Specify a listening link of either 0 or 1. UDP/IP links can be created by
configuring a matching pair of links, one on each end point. However, that
is error prone and doesn't scale. So UDP/IP links can also listen (in the TCP
sense), and dynamically create connected UDP/IP links when contacted.
Select this box to specify the MiNT link as a forced link.
Use the spinner control to define a link cost between 1 - 10,000. The default
value is 100.
Set an interval in either Seconds (1 - 120) or Minutes (1 - 2) for the
transmission of hello packets. The default interval is 15 seconds.
Set a hold time interval in either Seconds (2 - 600) or Minutes (1 - 10) for
the transmission of hello packets. The default interval is 46 seconds.
Device Configuration 5 - 91