xStack
DGS-3120 Series Layer 3 Managed Gigabit Switch CLI Reference Guide
<drive_id> - (Optional) Enter the drive ID used here. Examples are C: or D:
<pathname> - Specify the file to be deleted. If it is specified in the associated form, then it is
related to the current directory.
Restrictions
Only Administrator and Operator-level users can issue this command.
Example
To erase a file:
DGS-3120-24TC:admin#dir
Command: dir
Directory of /unit2:/c:
Idx Info
Attr Size
--- ------- ---- -------- ------------------- ----------------
1 CFG(b)
-rw- 29661
2 CFG(*)
-rw- 29661
3 RUN(*)
-rw- 4879040
4
d--- 0
29618 KB total (24697 KB free)
(*) -with boot up info
DGS-3120-24TC:admin#erase config2.cfg
Command: erase config2.cfg
Success.
DGS-3120-24TC:admin#dir
Command: dir
Directory of /unit2:/c:
Idx Info
Attr Size
--- ------- ---- -------- ------------------- ----------------
1 CFG(*)
-rw- 29661
2 RUN(*)
-rw- 4879040
3
d--- 0
29618 KB total (24727 KB free)
(*) -with boot up info
DGS-3120-24TC:admin#
Update Time
2000/04/02 06:03:19 config2.cfg
2000/04/01 05:54:38 config.cfg
2000/03/26 03:15:11 B019.had
2000/04/01 05:17:36 system
(b) -with backup info
Update Time
2000/04/01 05:54:38 config.cfg
2000/03/26 03:15:11 B019.had
2000/04/01 05:17:36 system
(b) -with backup info