Checking The G430 Hardware Vintage From Branch Gateway Cli - Avaya G430 Deploying And Upgrading

Branch gateway
Hide thumbs Also See for G430:
Table of Contents

Advertisement

Component
MM714 Analog Port/Trunk media module
MM714B Analog Port/Trunk media module
MM716 Analog Port/Trunk media module
MM717 DCP media module
MM720 BRI media module
MM721 BRI media module
MM722 BRI media module
Example failure message if the wrong image is used
The system displays a failure message if a wrong image is used. Run the following command:
show download software status 10
The system displays the following message:
Module #10
===========
Module
Source file
Destination file : G430-A
Host
Running state
Failure display
Last warning

Checking the G430 hardware vintage from Branch Gateway CLI

Checking the G430 hardware vintage from the Branch Gateway CLI
About this task
You can check the hardware vintage of the model before downloading the G430 software image.
Before you begin
Login to the application CLI interface.
Procedure
To check the hardware vintage, run the command:
show system and check the rows Model and HW Vintage.
• G430v1 displays the following message:
System Name
System Location
System Contact
July 2018
: 10
: g430_39_12_0.bin
: 135.9.1.75
: Idle
: Incompatible software image for this type of device
: No-warning
:
:
:
Deploying and Upgrading Avaya G430 Branch Gateway
Comments on this document? infodev@avaya.com
Branch Gateway firmware upgrades
File name Example
mm714v5.fdl
mm714h10v93.fdl
mm716v80.fdl
mm717v3.fdl
mm720v1.fdl
mm721v1.fdl
mm722v3.fdl
Notes