Polycom IP 320 Administrator's Manual page 44

Polycom soundpoint ip/soundstation ip/ vvx family
Hide thumbs Also See for IP 320:
Table of Contents

Advertisement

Administrator's Guide for the SoundPoint IP / SoundStation IP / VVX Family
Note
Note
Name
Boot Server
3 - 8
A parameter value of "???" indicates that the parameter has not yet been set and
saved in the phone's configuration. Any such parameter should have its value set
before continuing.
The EM Power parameter is only available on SoundPoint IP 650 and 670 phones.
To switch the text entry mode on the SoundPoint IP 32x/33x, press the #. You may
want to use URL or IP address modes when entering server addresses.
DHCP Menu
The DHCP menu is accessible only when the DHCP client is enabled. The
following DHCP configuration parameters can be modified on the DHCP
menu:
Possible
Values
Description
0=Option 66
The phone will look for option number 66 (string type) in the
response received from the DHCP server. The DHCP server
should send address information in option 66 that matches one
of the formats described for Server Address in the next
section,
If the DHCP server sends nothing, the following scenarios are
possible:
Server
Menu.
If a boot server value is stored in flash memory and the
value is not "0.0.0.0", then the value stored in flash is used.
Otherwise the phone sends out a DHCP INFORM query.
- If a single alternate DHCP server responds, this is
functionally equivalent to the scenario where the primary
DHCP server responds with a valid boot server value.
- If no alternate DHCP server responds, the INFORM query
process will retry and eventually time out.