Attribute
log.render.file.size
log.render.file.upload.period
log.render.file.upload.append
log.render.file.upload.append.sizeLimit
log.render.file.upload.append.limitMode
Attribute
log.sched.x.name
log.sched.x.level
log.sched.x.period
Permitted
Values
positive
integer, 1 to
179.5
positive
integer
0 or 1
positive
integer
delete, stop
Scheduled Logging Parameters <sched/>
The phone can be configured to schedule certain advanced logging tasks on a
periodic basis. These attributes should be set in consultation with Polycom
Technical Support. Each scheduled log task is controlled by a unique attribute
set starting with log.sched.x where x identifies the task.
Permitted
Values
Interpretation
alphanumeric
Name of an internal system command to be periodically executed.
string
To be supplied by Polycom.
0-5
Event class to assign to the log events generated by this command.
This needs to be the same or higher than log.level.change.slog for
these events to appear in the log.
positive
Seconds between each command execution. 0=run once
integer
Default
Interpretation
16
Maximum local application log file
size in Kbytes. When this size is
exceeded, the file is uploaded to
the provisioning server and the
local copy is erased.
172800
Time in seconds between log file
uploads to the provisioning server.
Note: The log file will not be
uploaded if no new events have
been logged since the last upload.
1
If set to 1, use append mode when
uploading log files to server.
Note: HTTP and TFTP don't
support append mode unless the
server is set up for this.
512
Maximum log file size on
provisioning server in Kbytes.
delete
Behavior when server log file has
reached its limit.
delete=delete file and start over
stop=stop appending to file
Configuration Files