The parameters for log level settings are found in the sip.cfg configuration file.
They are log.level.change.module_name. Log levels range from 1 to 6 (1 for
the most detailed logging, 6 for critical errors only). There are currently 27
different log types that can be adjusted to assist with the investigation of
different problems.
When testing is complete, remember to return all logging levels to the default
value of 4.
There are other logging parameters that you may wish to modify. Changing
these parameters does not have the same impact as changing the logging
levels, but you should still understand how your changes will affect the phone
and the network.
log.render.level—Sets the lowest level that can be logged (default=1)
log.render.file.size—Maximum size before log file is uploaded
(default=16 kb)
log.render.file.upload.period—Frequency of log uploads (default is
172800 seconds = 48 hours)
log.render.file.upload.append—Controls if log files on the
provisioning server are overwritten or appended, not supported by all
servers
log.render.file.upload.append.sizeLimit—Controls the maximum
size of log files on the provisioning server (default=512 kb)
log.render.file.upload.append.limitMode—Controls action to take
when server log reaches max size, actions are stop and delete
Scheduled Logging
Scheduled logging is a powerful tool for anyone who is trying to troubleshoot
an issue with the phone that only occurs after some time in operation.
The output of these instructions is written to the application log, and can be
examined later (for trend data).
The parameters for scheduled logging are found in the sip.cfg configuration
file. They are log.sched.module_name.