Brocade Communications Systems Brocade 8/12c Command Reference Manual page 107

Brocade fabric os command reference manual supporting fabric os v7.0.0 (april 2011)
Hide thumbs Also See for Brocade 8/12c:
Table of Contents

Advertisement

6 seconds in an interval of 10 seconds, and 1 second out of the other 4 seconds was affected by a
bottleneck, the display for that interval would show 25% as the percentage of affected seconds (1 out of
4), and state "no data for 6 seconds." However, if there is no traffic because the port is offline, the "no
data..." message is displayed.
The --status option displays bottleneck configuration details for the current (logical) switch. If virtual
fabrics are enabled, ports not belonging to the current logical switch are not displayed. The command
output includes the following information:
Bottleneck detection
Switch-wide sub-second latency bottleneck criterion
Switch-wide alerting parameters
Per-port overrides for sub-second latency bottleneck criterion
Per-port overrides for alert parameters
Excluded ports
Fabric OS Command Reference
53-1001764-01
Enabled or disabled
Displays the following parameters:
Time threshold
The value set with the -lsubsectimethresh operand.
Severity threshold
The value set with the -lsubsecsevthresh operand.
Displays the following parameters:
Alerts?
Yes (enabled) or No (disabled).
Congestion threshold for alert
The severity threshold for triggering a congestion alert. This threshold indicates
the percentage of one-second intervals affected by congestion conditions within a
specified time window. The congestion threshold is expressed as a fraction
between 0 and 1.
Latency threshold for alert
The severity threshold for triggering a latency alert. This threshold indicates the
percentage of one-second intervals affected by latency conditions within a
specified time window. The latency threshold is expressed as a fraction between 0
and 1.
Averaging time for alert
The time window in seconds over which the percentage of seconds affected by
bottleneck conditions is computed and compared with the threshold.
Quiet time for alert
The minimum number of seconds between consecutive alerts. The value
assigned to this parameter applies to both latency and congestion detection.
Custom configuration for the above mentioned sub-second latency bottleneck
parameters. Note that everything above this line applies to all ports in the switch
that don't have any custom configuration or exclusions.
Custom configuration for the above mentioned alert parameters.
List of ports excluded from bottleneck detection.
22
bottleneckMon
73

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fabric os v7.0.0

Table of Contents