33
Displaying 802.1x information
Syntax: clear dot1x mac-session <mac-address>
Displaying 802.1x information
You can display the following 802.1x-related information:
•
•
•
•
•
Displaying 802.1x configuration information
To display information about the 802.1x configuration on the BigIron RX device, enter the following
command.
BigIron RX# show dot1x
PAE Capability
system-auth-control
Number of ports enabled
re-authentication
global-filter-strict-security: Enable
quiet-period
tx-period
supptimeout
servertimeout
maxreq
re-authperiod
Protocol Version
auth-fail-action
MAC Session Aging
MAC Session Max Age
Maximum Failed Attempts
Syntax: show dot1x
The following table describes the information displayed by the show dot1x command.
TABLE 157
This field...
PAE Capability
system-auth-control
Number of ports enabled
966
Information about the 802.1x configuration on the device and on individual ports
Statistics about the EAPOL frames passing through the device
Information about 802.1x-enabled ports dynamically assigned to a VLAN
Information about the user-defined and dynamically applied Mac address and IP ACLs
currently active on the device
Information about the 802.1x multiple client configuration
Output from the show dot1x command
: Authenticator Only
: Enable
: 25
: Disable
: 60 Seconds
: 30 Seconds
: 30 Seconds
: 30 Seconds
: 3
: 3600 Seconds
: 1
: Block Traffic
: All
: 120 Seconds
: 3
Displays...
The Port Access Entity (PAE) role for the BigIron RX device. This is always
"Authenticator Only".
Whether system authentication control is enabled on the device. The
dot1x-enable command enables system authentication control on the
device.
Number of interfaces on the devices that have been enabled for 802.1x.
BigIron RX Series Configuration Guide
53-1001986-01