Re-enabling an interface
•
Re-enabling an interface
The violation action of violation shutdown or violation restrict have options that can be configured
to cause an interface to shutdown. If the shutdown option is selected, the following options can be
used to re-enable an interface.
Interface shutdown time
You can specify how long an interface remains shutdown when violation shutdown or violation
restrict is configured. For example, you can enter commands such as the following.
BigIron RX(config)# int e 7/11
BigIron RX(config-if-e100-7/11)#port security
BigIron RX(config-port-security-e100-7/11)# violation shutdown
BigIron RX(config-port-security-e100-7/11)#shutdown-time 60
Syntax: [no] shutdown-time <minutes>
Enter 0 – 1440 minutes, with 0 as the default. Specifying 0 shuts down the interface permanently
when a MAC Port Security violation occurs.
Manually re-enabling a interface
Once an interface is permanently shut down, an administrator must re-enable the interface by
entering the following command.
BigIron RX(config)# int e 7/11
BigIron RX(config-if-e100-7/11)#enable
Syntax: enable
Displaying MAC Port Security information
The following sections present the reports that can be displayed for MAC Port Security.
Displaying MAC Port Security settings
You can display the MAC Port Security settings for the device.