Changing The Is-Is Level Globally; Disabling Or Re-Enabling Display Of Hostname; Changing The Sequence Numbers Pdu Interval - Dell PowerConnect B-RX Configuration Manual

Bigiron rx series supporting multi-service ironware v02.7.03
Hide thumbs Also See for PowerConnect B-RX:
Table of Contents

Advertisement

28
Globally configuring IS-IS on a device

Changing the IS-IS Level globally

By default, a BigIron RX can operate as both a Level-1 and IS-IS Level-2 router. To globally change
the level supported from Level-1 and Level-2 to Level-1 only, enter the following command.
BigIron RX(config-isis-router)# is-type level-1
Syntax: [no] is-type level-1 | level-1-2 | level-2
The level-1 | level-1-2 | level-2 parameter specifies the IS-IS type. If you want to re-enable support
for both IS-IS types, re-enter the command you entered to change the IS-IS type, and use "no" in
front of the command.
To change the IS-IS on an interface, refer to

Disabling or re-enabling display of hostname

Brocade's implementation of IS-IS supports RFC 2763, which describes a mechanism for mapping
IS-IS system IDs to the hostnames of the devices with those IDs. For example, if you set the
hostname on the device to "IS-IS Router 1", the mapping feature uses this name instead of the
device's IS-IS system ID in the output of the following commands.
The device's hostname is displayed in each CLI command prompt, for example.
BigIron RX(config-isis-router)#
The name mapping feature is enabled by default. If you want to disable name mapping, enter the
following command.
BigIron RX(config-isis-router)# no hostname.
Syntax: [no] hostname
To display the name mappings, enter the show isis hostname command.

Changing the sequence numbers PDU interval

A Complete Sequence Numbers PDU (CSNP) is a complete list of the LSPs in the Designated IS' link
state database. The CSNP contains a list of all the LSPs in the database, as well as other
information that helps IS neighbors determine whether their LSP databases are in sync with one
another. The Designated IS sends CSNPs to the broadcast interface. Level-1 and Level-2 each have
their own Designated IS.
A Partial Sequence Numbers PDU (PSNP) is a partial list of LSPs. ISs other than the Designated IS
(that is, the non-Designated ISs) send PSNPs to the broadcast interface.
The CSNP interval specifies how often the Designated IS sends a CSNP to the broadcast interface.
Likewise, the PSNP interval specifies how often other ISs (non-Designated ISs) send a PSNP to the
broadcast interface.
The interval you can configure on the device applies to both Level-1 and Level-2 CSNPs and PSNPs.
The default interval is 10 seconds. You can set the interval to a value from 0 – 65535 seconds.
To change the interval, enter a command such as the following.
866
show isis database
show isis interface
show isis neighbor
"Changing the IS-IS level on an interface"
BigIron RX Series Configuration Guide
on page 878.
53-1001986-01

Advertisement

Table of Contents
loading

This manual is also suitable for:

Bigiron rx series

Table of Contents