The on-startup <secs> parameter specifies the number of seconds following a reload to set the
overload bit on. You can specify 0 or a number from 5 – 86400 (24 hours). The default is 0, which
means the device starts performing IS-IS routing immediately following a successful software
reload.

Configuring authentication

By default, the BigIron RX does not authenticate packets sent to or received from ESs or other ISs.
You can configure the following types of passwords for IS-IS globally.
TABLE 131
Password type
Domain
Area
Interface
If you configure a password, the device checks for the password in IS-IS packets received by the
device and includes the password in packets sent by the device. For example, the device checks all
Level-2 LSPDUs received by the device for the domain password you configure, and includes the
password in all Level-2 PDUs sent by the device.
Configuring a domain password
To configure an IS-IS domain password, enter a command such as the following.
BigIron RX(config-isis-router)# domain-password domain-1
This command configures the device to use the password "domain-1" to authenticate Level-2
LSPDUs.
Syntax: [no] domain-password <string>
The <string> parameter specifies the password. You can enter an alphanumeric string up to 80
characters long. The password can contain blank spaces. If you use a blank space in the password,
you must use quotation marks (" ") around the entire password; for example, domain-password
"domain 1".
Configuring an area password
To configure an IS-IS area password, enter a command such as the following.
BigIron RX(config-isis-router)# area-password area-51
This command configures the device to use the password "area-51" to authenticate Level-1
LSPDUs.
Syntax: [no] area-password <string>
The <string> parameter specifies the password. You can enter an alphanumeric string up to 80
characters long. The password can contain blank spaces. If you use a blank space in the password,
you must use quotation marks (" ") around the entire password; for example, area-password "area
51".
BigIron RX Series Configuration Guide
53-1001986-01
IS-IS passwords
Scope
Level-2
Level-1
Level-1 and Level-2
Globally configuring IS-IS on a device
Where used
Default
Level-2 LSPDU
None configured
Level-1 LSPDU
None configured
Hello PDU
None configured