Signal Name
Description
STP.SWIN. +
Rotates forward with 24 V power supply.
STP.SWIN. -
Rotates reversely with 24 V power supply.
STAPLE M. +
Rotates forward with 24 V power supply.
STAPLE M. -
Rotates reversely with 24 V power supply.
STP.SWING H.1 Detects the dual position angle of the 45° stapling.
5 V = Not home position, 0 V = Home position.
STP.SWING H.2 Detects the dual position angle of the 45° stapling.
5 V = Not home position, 0 V = Home position.
NEEDLE
Detects the presence of staples.
0 V = Staple present, 5 V = No staple.
STPLE HOME
Detects the home position at stapling operation.
5 V = Not home position, 0 V = Home position.
NEEDLE HOME Detects the home position at staple supply.
5 V = Not home position, 0 V = Home position.
CARTRIDGE
Detects the presence of staples.
0 V = Cartridge present in Staple, 5 V = No Cartridge in Staple.
STPLE HOME
Detects the home position at stapling operation.
5 V = Not home position, 0 V = Home position.