Signal Name
Description
EJECT A
Rotates the Ejector Open/Shut Motor by pulse signals from the Finisher Main PWB.
EJECT /A
Rotates the Ejector Open/Shut Motor by pulse signals from the Finisher Main PWB.
EJECT B
Rotates the Ejector Open/Shut Motor by pulse signals from the Finisher Main PWB.
EJECT /B
Rotates the Ejector Open/Shut Motor by pulse signals from the Finisher Main PWB.
STACK A
Rotates the Stack Motor by pulse signals from the Finisher Main PWB.
STACK /A
Rotates the Stack Motor by pulse signals from the Finisher Main PWB.
STACK B
Rotates the Stack Motor by pulse signals from the Finisher Main PWB.
STACK /B
Rotates the Stack Motor by pulse signals from the Finisher Main PWB.
EJECT A
Rotates the Eject Motor by pulse signals from the Finisher Main PWB.
EJECT /A
Rotates the Eject Motor by pulse signals from the Finisher Main PWB.
EJECT B
Rotates the Eject Motor by pulse signals from the Finisher Main PWB.
EJECT /B
Rotates the Eject Motor by pulse signals from the Finisher Main PWB.
SHIFT A
Rotates the Shift Motor by pulse signals from the Finisher Main PWB.
SHIFT /A
Rotates the Shift Motor by pulse signals from the Finisher Main PWB.
SHIFT B
Rotates the Shift Motor by pulse signals from the Finisher Main PWB.
SHIFT /B
Rotates the Shift Motor by pulse signals from the Finisher Main PWB.
JOG (L)A
Rotates the Jogging Motor by pulse signals from the Finisher Main PWB.
JOG (L)/A
Rotates the Jogging Motor by pulse signals from the Finisher Main PWB.
JOG (L)B
Rotates the Jogging Motor by pulse signals from the Finisher Main PWB.
JOG (L)/B
Rotates the Jogging Motor by pulse signals from the Finisher Main PWB.
JOG (R)A
Rotates the Jogging Motor (L) by pulse signals from the Finisher Main PWB.
JOG (R)/A
Rotates the Jogging Motor (L) by pulse signals from the Finisher Main PWB.
JOG (R) B
Rotates the Jogging Motor (L) by pulse signals from the Finisher Main PWB.
JOG (R) /B
Rotates the Jogging Motor (L) by pulse signals from the Finisher Main PWB.
5-20
Service Manual
4025-Finisher