Tray Harness Assembly Removal

Removal
1.
Remove the Rear Cover.
2.
Open the Top Cover of the H-Tra.
3.
Remove the Sensor.
4.
Unclamp the H-Tra harness assembly at seven places on the H-Tra.
5.
Unclamp the H-Tra harness assembly at four places on the H-Tra.
6.
Unplug the connector (P/J 256M) of the solenoid assembly.
7.
Unplug three connectors (P/J 882A,879A,880A) of the harness connection, and
remove the harness connection.
8.
Unplug the connector (P/J 260) of the H-Tra harness assembly from the sensor.
9.
From the lower side, tighten the latch of clamp on the bracket assembly with radio
pliers to release the H-Tra harness assembly together with the clamp.
10.
Pull the connector (P/J 263) and the harness of the spring tension 80 off the hole on
the rear of the H-Tra.
11.
Pull the connectors (P/J 275M,259) and the harnesses of the spring tension 80 and
sensor full off the hole on the rear of the H-Tra.
12.
Unclamp the H-Tra harness assembly at four places on the bracket assembly, and
remove the tray harness assembly.