DWS-1008 CLI Reference Guide
show snmp usm
Displays information about SNMPv3 users.
Defaults: None
Access: Enabled
Examples: To display USM settings, use the following command:
DWS-1008# show snmp usm
USM users:
"nmsuser", engineID=localSnmpID
access=read-notify
auth=NONE
encrypt=NONE
notify target use cnt=0
The table below describes the fields in this display.
Field
USM name
engineID
access
auth
encrypt
notify target use cnt
D-Link Systems, Inc.
Description
Name of the SNMPv3 user.
Engine ID for the USM name, which is either the local switch or the
notification target where informs are to be sent.
Access settings for the string:
• read-only - an SNMP management application using
the string can get (read) object values on the switch but
cannot set (write) them.
• read-notify - An SNMP management application using
the string can get object values on the switch but cannot
set them. The switch can use the string to send notifications.
• notify-only - The switch can use the string to send
notifications.
• read-write - An SNMP management application using the
string can get and set object values on the switch.
• notify-read-write - An SNMP management application using
the string can get and set object values on the switch. The
switch can use the string to send notifications.
Authentication type:
• md5
• sha
• none
Encryption (privacy) setting:
• des
• 3des
• aes
• none
Number of times this community is specified in a notification target
entry.