Omron OMNUC G5 User Manual page 408

Ac servomotors/servo drives
Table of Contents

Advertisement

8-5 Interface Monitor Setting Parameters
Pn435
Speed Conformity Detection Width
Setting
range
When speed command and motor speed are identical, speed conformity output signal is output.
This setting has a hysteresis of 10 r/min for detection.
Speed [r/min]
Pn435
Speed Conformity
Detection Range
Speed conformity
output
Pn436
Rotation Speed for Motor Rotation Detection
Setting
range
8
Speed reached output signal is output when the motor speed reaches the speed set as the
achieved speed.
This setting has a hysteresis of 10 r/min for detection.
Speed [r/min]
Pn436+10
Pn436−10
− (Pn436−10)
− (Pn436+10)
Speed reached
output
8-43
10 to 20,000
Unit
A speed command after the acceleration
Speed command
/deceleration processing
ON
OFF
10 to 20,000
Unit
OFF
ON
OMNUC G5-SERIES AC SERVOMOTOR AND SERVO DRIVE USER'S MANUAL
Default
r/min
setting
Motor speed
Pn435
Speed Conformity Detection Range
ON
Default
r/min
setting
Motor speed
OFF
ON
Speed
Power OFF
and ON
Pn435
Speed Conformity Detection Range
OFF
Speed
Power OFF
and ON
Time
Time

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Omnuc g5 seriesR88m-k seriesR88d-kt

Table of Contents