Omron OMNUC G5 User Manual page 243

Ac servomotors/servo drives
Table of Contents

Advertisement

Terminal Block Wiring Procedure
On a driver with 2.0 kW or less, a connector-type terminal block is used.
The procedure for wiring these terminal blocks is explained below.
Connector-type
terminal block
1. Remove the terminal block from the driver before wiring.
The driver will be damaged if the wiring is done with the terminal block in place.
2. Strip off 8 to 9 mm of the covering from the end of each wire.
Refer to "Terminal Block Wire Sizes"(P.4-17) for applicable wire sizes.
3. Open the wire insertion slots in the terminal block using a tool.
There are 2 ways to open the wire insertion slots, as follows.
Pry the slot open using the lever that comes with the Servo Drive. (Figure A)
Insert a flat-blade screwdriver (end width: 3.0 to 3.5 mm) into the opening for the driver of the
terminal block, and press down firmly to open the slot. (Figure B)
4. With the wire insertion slot held open, insert the end of the wire.
After inserting the wire, let the slot close by releasing the pressure from the lever or the
screwdriver.
5. Mount the terminal block to the driver.
After all of the terminals have been wired, return the terminal block to its original position on
the Servo Drive.