External Feedback Pulse Error Setting (Pn328, Pn329)
The difference between the encoder position and external scale position is detected, and if the
difference exceeds the value of Internal/External Feedback Pulse Error Counter Overflow
Level (Pn328), an error will occur.
Parameter
number
Pn328
Pn329
Pn329: Internal/External Feedback Pulse Error Counter Reset
Every time the motor rotates for the amount set by Pn329, the internal/external feedback pulse
error is cleared.
This function can be used when there is deviation between the position calculated from
encoder pulses and the position calculated from external scale due to slipping, etc, and
internal/external feedback pulse errors accumulate.
Amount of internal/external feedback pulse error
[command unit]
Pn328 Internal/External Feedback Pulse Error Counter Overflow Level
Pn329
Internal/External Feedback
Pulse Error Counter Reset
Precautions for Correct Use
An internal/external feedback pulse error counter overflow level error occurs when the external
scale is abnormal, connection is wrong, or connection point between the motor and load is loose,
among others. Accordingly, check these items when an error occurs.
Be sure to set an appropriate value for Internal/External Feedback Pulse Error Counter Reset
(Pn329). If an extremely small value is set, this function may not operate.
Use with extra caution on safety by installing limit sensors, etc.
OMNUC G5-SERIES AC SERVOMOTOR AND SERVO DRIVE USER'S MANUAL
Parameter name
Internal/External
Set the allowable difference (hybrid error)
Feedback Pulse
between the encoder-detected position
Error Counter
and external scale-detected position in
Overflow Level
the command unit.
Internal/External
The hybrid error becomes 0 every time
Feedback Pulse
the motor rotates by the set value. If the
Error Counter
set value is 0, the hybrid error is not
Reset
cleared.
0 clear
Pn329
Internal/External Feedback
Pulse Error Counter Reset
5-6 Full Closing Control
Explanation
Error detection
0 clear
Pn329
Internal/External Feedback
Pulse Error Counter Reset
Setting
Unit
range
Command
27
1 to 2
unit
0 to 100
Rotation
Number of motor
rotations [rotation]
5-30
5