Setting First Slot Words - Omron CS1D DUPLEX SYSTEM - 10-2009 Operation Manual

Cs1d duplex system
Table of Contents

Advertisement

Allocating First Words to Slots (Single CPU Systems Only)
Group 00 set for first
slot word of CIO 0000
Rack number 0
Rack number 1
Rack number 2
Rack number 3
Setting First Slot Words from the CX-Programmer
1,2,3...
238
Example: Setting the First Words for Racks
In this example, a first slot word has been set in the middle of each Rack. For
simplicity, only 16-bit Units have been used.
Group 01 set for first
slot word of CIO 0200
Group 03 set for first
Group 05 set for first
slot word of CIO 0500
slot word of CIO 0600
First Slot Word Settings
Group
00 (See note.)
01
02
03
04
05
Note Group 00 must start at slot 00 on the CPU Rack. Any word can be set. Any
slot can be set on any Rack for groups 01 to 63.
First slot words can be set from the CX-Programmer. These settings are not
possible from a Programming Console.
1. Select the Rack/Slot Start Addresses from the Option Menu on the I/O
Table Window. The following dialog box will be displayed.
Group 02 set for first slot word of CIO 0200
Group 04 set for first slot word of CIO 0300
Rack
CPU Rack
00
CPU Rack
03
Rack 1
04
Rack 2
00
Rack 3
05
Rack 4
05
Section 7-4
CPU Rack
CS1D Expansion Rack
CS1D Expansion Rack
CS1D Expansion Rack
Slot
Word
CIO 0000
CIO 0100
CIO 0200
CIO 0500
CIO 0300
CIO 0600

Advertisement

Table of Contents
loading

Table of Contents