Programming Devices
Connections
Personal computer
IBM PC/AT or com-
patible
CS1W-CN118
CS1W-CN226
CS1W-CN616
(See note 1.)
CX-Programmer Connecting Cables
Unit
Unit port
CPU Units
Peripheral
port
Built-in RS-
232C port
D-Sub, 9-pin,
female
Serial Com-
RS-232C
munications
Port
Boards/Units
D-Sub, 9-pin,
(See note 1.)
female
74
Peripheral port connection
9-pin male
DUPLEX
Peripheral port
9-pin
10-pin female
female
CS1W-CN118 (0.1 m) (See note 1.)
CS1W-CN226 (2.0 m)
CS1W-CN616 (6.0 m)
9-pin
female
Note
1. The CS1W-CN118 Cable is used with one of the RS-232C Cables shown
on the right (XW2Z-@@@S-@@) to connect to the peripheral port on the
CPU Unit.
2. If cables with model numbers ending in -V instead of -CV are used to con-
nect the computer running the CX-Programmer to the RS-232C port (in-
cluding when using a CS1W-CN118 Cable), a peripheral bus connection
cannot be used. Use a Host Link (SYSWAY) connection. To connect to the
port using a peripheral bus connection, prepare an RS-232C cable as de-
scribed in Connection Methods on page 77.
Computer
Computer
port
IBM PC/AT or
D-Sub, 9-
compatible
pin, male
IBM PC/AT or
D-Sub, 9-
compatible
pin, male
IBM PC/AT or
D-Sub, 9-
compatible
pin, male
Note
1. Serial Communications Boards are supported only for Single CPU Sys-
tems.
2. Before connecting a connector from the above table to a PLC RS-232C
port, touch a grounded metal object to discharge static electricity from your
body. The XW2Z-@@@S-CV Cables have been strengthened against stat-
ic because they use a static-resistant connector hood (XM2S-0911-E).
Even so, always discharge static electricity before touching the connectors.
3. Do not use commercially available RS-232C personal computer cables. Al-
ways use the special cables listed in this manual or make cables according
9-pin male
XW2Z-200S-CV/200S-V (See note 2.)
XW2Z-500S-CV/500S-V (See note 2.)
XW2Z-200S-
CV/200S-V or
XW2Z-500S-
10-pin
CV/500S-V
DUPLEX
RS-232C Cable
CS1W-CN118
Serial
communications
mode
Peripheral bus or
Host Link
Peripheral bus or
Host Link
Host Link
Section 2-6
RS-232C port connection
DUPLEX
9-pin
male
9-pin
RS-232C port
female
9-pin female
9-pin
female
Peripheral port
Model
Length Cable notes
CS1W-CN226
2.0 m
CS1W-CN626
6.0 m
XW2Z-200S-CV 2 m
XW2Z-500S-CV 5 m
XW2Z-200S-CV 2 m
XW2Z-500S-CV 5 m
9-pin
male
---
Use a static-
resistant con-
nector.
Use a static-
resistant con-
nector.

Advertisement

Table of Contents
loading

Table of Contents