Omron CS1D DUPLEX SYSTEM - 10-2009 Operation Manual page 45

Cs1d duplex system
Table of Contents

Advertisement

System Configuration
Name
3
CS1D Power Supply
Units
4
CPU Backplane for
Duplex CPU Systems
(Especially for a
Duplex CPU, Dual I/O
Expansion System)
5
CS1D I/O Control
Unit (Especially for a
Duplex CPU, Dual I/O
Expansion System)
CS1D CPU Rack for a Duplex CPU, Single I/O Expansion System
4) CS1D-BC052 CPU
Backplane for Duplex CPU
Systems (See note.)
A maximum of 5 Units can be mounted.
CS-series Basic I/O Units
CS-series Special I/O Units and CPU
Bus Units
Note: C200H Units cannot be mounted.
Name
1
Duplex Unit
(Especially for a Duplex
CPU, Single I/O Expan-
sion System)
2
CPU Units for Duplex
CPU Systems
Model number
CS1D-PA207R
CS1D Power Supply Units are designed especially for a Duplex
CS1D-PD024
System. Two Power Supply Units are mounted to a CPU Rack,
CS1D-PD025
Expansion Rack, or Long-distance Expansion Rack for a duplex
power supply configuration. When not configuring a duplex power
supply, only one Power Supply Unit is mounted.
CS1D-BC042D
A CPU Backplane for Duplex CPU System is used in a Duplex CPU
System. It allows the mounting of Duplex CPU Units, Duplex Power
Supply Units, and Duplex Communications Units, as well as online
Unit replacement and online Duplex Unit replacement.
These Backplanes cannot be used as Backplanes for Long-dis-
tance Expansion Racks.
CS1D-IC102D
These Units are required to create a Duplex CPU, Dual I/O Expan-
sion System. The Connecting Cables can be duplexed by using two
of these Units.
These I/O Control Units cannot be used in a Duplex CPU, Single
I/O Expansion System.
Note When using a Memory Card in Duplex Mode, mount it in the active CPU Unit.
(Duplex Memory Card operation is not possible.) Duplex EM File Memory
operation is possible.
2) CS1D-
1) CS1D-DPL01
Duplex Unit
RUN
ERR/ALM
INH
BKUP
PRPHL
COMM
SYSMAC
CS1D-CPU67H
PROGRAMMABLE CONTROLLER
MCPWR
BUSY
OPEN
PERIPHERAL
PORT
Duplex CPU Units
Model number
CS1D-DPL01
The Duplex Unit is the Unit that controls duplex system operation. It
monitors for errors and switches operation when an error occurs.
This Duplex Unit cannot be used in a Duplex CPU, Dual I/O Expan-
sion System.
CS1D-CPU65H
CPU Units for Duplex CPU System are designed especially for a
CS1D-CPU67H
Duplex CPU System. Two CPU Units of the identical model are
CS1D-CPU65P
mounted.
CS1D-CPU67P
These CPU Units cannot be used in a Single CPU System.
Contents
CPU65H/67H/65P/67P
3) CS1D-PA207R
CPU Units for Duplex
CS1D-PD024/025
CPU Systems
Power Supply Units
DPL01
DPL STATUS
RUN
ACTIVE
L
ERR/ALM
CPU STATUS
INH
ACTIVE
BKUP
R
CPU STATUS
PRPHL
COMM
LEFT CPU
SYSMAC
CS1D-CPU67H
USE
PROGRAMMABLE CONTROLLER
NO USE
RIGHT CPU
USE
MCPWR
BUSY
NO USE
OPEN
DPL SW
ON
OFF
SPL
DPL
ACT.
ACT.
LEFT
RIGHT
ON
PERIPHERAL
INIT.
SW
PRPHL
COMM
A39512
RSV
ON
PORT
DUPLEX
DUPLEX
Duplex Power
Supply Units
Contents
Section 1-2
CS1D CPU Rack
9

Advertisement

Table of Contents
loading

Table of Contents