Replacing User-serviceable Parts
Replacement Battery
Replacement Battery
!Caution We recommend replacing the battery with the power OFF to prevent the CPU
Unit Versions and Corresponding Battery Replacement Methods
Type
CPU Simplex Sys-
Unit Ver. 2.0
tem
CPU Duplex System No unit version
Unit Ver. 1.1
Unit Ver. 1.2 or later
428
RUN
ERR/ALM
INH
BKUP
PRPHL
COMM
When the ERR/ALM indicator flashes, connect the CX-Programmer to the
peripheral port and read the error message. If the message "BATT LOW"
appears on the Programming Console* and the Battery Error Flag (A40204) is
ON*, first check whether the battery is properly connected to the CPU Unit. If
the battery is properly connected, replace the battery as soon as possible.
BATT LOW
Once a low-battery error has been detected, it will take 5 days before the bat-
tery fails. Battery failure can be delayed by ensuring that the CPU Unit power
is not turned OFF until the battery has been replaced.
Note *The PLC Setup must be set to detect a low-battery error (Detect Low Bat-
tery). If this setting has not been made, the BATT LOW error message will not
appear on the Programming Console and the Battery Error Flag (A40204) will
not go ON when the battery fails.
Install a replacement battery within 2 years of the production date shown on
the battery's label.
Use the following replacement battery: CS1W-BAT01 Battery Set
Production Date
CS1W-BAT01
02
6
Manufactured in June 2002.
The battery replacement method depends on whether a CPU Unit is used in a
duplex or simplex system, and on the CPU Unit's unit version.
Unit's sensitive internal components from being damaged by static electricity.
The battery can be replaced with the power ON, but be sure to touch a
grounded metal object to discharge any static electricity before replacing the
battery. After replacing the battery, connect a Programming Device and clear
the battery error.
Unit version
Number of
battery
connectors
1
1
2
Replacement
Replacement method
time (see note)
3 min.
Refer to Replacement Procedure
for CS1-H (Pre-Ver. 2.0 and Ver.
2.0) CPU Units with One Battery
Connectors.
3 min.
Refer to Replacement Procedure
for CPU Units with One Battery
Connector.
3 min.
Refer to Replacement Procedure
for CPU Units with Two Battery
Connectors.