Auxiliary Area Allocations
Address
Name
Words
Bits
A344
All
EM File
Memory
Starting
Bank
A346
All
Number of
and
Remain-
A347
ing Words
to Transfer
A351 to
All
Calendar/
A354
Clock Area
A35100
to
A35107
A35108
to
A35115
A35200
to
A35207
A35208
to
A35215
A35300
to
A35307
A35308
to
A35315
A35400
to
A35407
524
Function
Contains the starting bank number
of EM file memory (bank number of
the first formatted bank). All EM
banks from this starting bank to the
last bank in EM are formatted for
use as file memory.
To convert the EM Area for use as
file memory, first set the PLC
Setup's EM File Memory Function
setting to 1, set the PLC Setup's EM
File Memory Starting Bank setting (0
to C), and then format the EM Area
from a Programming Device
The PLC Setup's EM file memory
settings won't agree with the actual
settings unless the EM Area is for-
matted after the PLC Setup's EM file
memory settings have been
changed. In that case, the actual
settings can be determined with this
word.
These words contain the 8-digit
hexadecimal number of words
remaining to be transferred by
FREAD(700) or FWRIT(701). When
one of these instructions is exe-
cuted, the number of words to be
transferred is written to A346 and
A347.
While the data is being transferred,
the value in these words is decre-
mented.
A326 contains the rightmost 4-digits
and A347 contains the leftmost 4-
digits.
Check the content of these words to
determine whether or not the
planned number of words have been
transferred successfully.
These words contain the CPU Unit's
internal clock data in BCD. The clock
can be set from a Programming
Device such as a Programming
Console, with the DATE(735)
instruction, or with a FINS command
(CLOCK WRITE, 0702).
Seconds (00 to 59) (BCD)
Minutes (00 to 59) (BCD)
Hours (00 to 23) (BCD)
Day of the month (01 to 31) (BCD)
Month (01 to 12) (BCD)
Year (00 to 99) (BCD)
Day of the week (00 to 06) (BCD)
00: SUN, 01: MON, 02: TUE,
03: WED, 04: THU,05: FRI, 06: SAT
Settings
Status
after
mode
change
0000 to 000C
Held
hex
Bank 0 to C
Data remaining
Held
in transfer
---
Held
Appendix B
Status at
Timing
Related
startup
flags,
settings
Held
When EM
PLC
file for-
Setup
matting is
(EM File
performed
Memory
Func-
tion set-
ting and
EM File
Memory
Starting
Bank
setting)
Cleared
Written as
---
FREAD or
FWRIT is
being exe-
cuted.
Decre-
mented as
data is
actually
trans-
ferred.
Held
Written
---
every
cycle

Advertisement