Auxiliary Area Allocations
Address
Name
Words
Bits
A355
A35500
Inner
to
Board
A35515
Monitor-
ing Area
(Single
CPU Sys-
tems or
Process-
control
CPU Units
only)
A360 to
A36001
Executed
A391
to
FAL Num-
A39115
ber Flags
A392
A39204
RS-232C
Port Error
Flag
A39205
RS-232C
Port Send
Ready
Flag (No-
protocol
mode)
A39206
RS-232C
Port
Reception
Com-
pleted
Flag
(No-proto-
col mode)
A39207
RS-232C
Port
Reception
Overflow
Flag
(No-proto-
col mode)
A39212
Peripheral
Port Com-
munica-
tions Error
Flag
A393
A39300
RS-232C
to
Port PT
A39307
Communi-
cations
Flag
A39308
RS-232C
to
Port PT
A39315
Priority
Regis-
tered
Flags
A39300
RS-232C
to
Port
A39315
Reception
Counter
(No-proto-
col mode)
Function
The function of these words is
defined by the Inner Board.
The flag corresponding to the speci-
fied FAL number will be turned ON
when FAL(006) is executed. Bits
A36001 to A39115 correspond to
FAL numbers 001 to 511.
The flag will be turned OFF when
the error is cleared.
ON when an error has occurred at
the RS-232C port. (Not valid in
peripheral bus mode or NT Link
mode.)
ON when the RS-232C port is able
to send data in no-protocol mode.
ON when the RS-232C port has
completed the reception in no-proto-
col mode.
When the number of bytes was
specified: ON when the specified
number of bytes is received.
When the end code was specified:
ON when the end code is received
or 256 bytes are received.
ON when a data overflow occurred
during reception through the RS-
232C port in no-protocol mode.
When the number of bytes was
specified: ON when more data is
received after the reception was
completed but before RXD(235) was
executed.
When the end code was specified:
ON when more data is received after
the end code was received but
before RXD(235) was executed.
ON when 257 bytes are received
before the end code.
ON when a communications error
has occurred at the peripheral port.
(Not valid in peripheral bus mode or
NT Link mode.)
The corresponding bit will be ON
when the RS-232C port is communi-
cating with a PT in NT link mode.
Bits 0 to 7 correspond to units 0 to 7.
The corresponding bit will be ON for
the PT that has priority when the
RS-232C port is communicating in
NT link mode.
Bits 0 to 7 correspond to units 0 to 7.
Indicates (in binary) the number of
bytes of data received when the RS-
232C port is in no-protocol mode.
Settings
Status
after
mode
change
---
Deter-
mined by
Inner
Board
ON: That FAL
Held
was executed
OFF: That FAL
wasn't executed
ON: Error
Held
OFF: No error
ON: Able-to-
Held
send
OFF: Unable-to-
send
ON: Reception
Held
completed
OFF: Reception
not completed
ON: Overflow
Held
OFF: No over-
flow
ON: Error
Held
OFF: No error
ON: Communi-
Held
cating
OFF: Not com-
municating
ON: Priority reg-
Held
istered
OFF: Priority not
registered
---
Held
Appendix B
Status at
Timing
Related
startup
flags,
settings
Deter-
---
---
mined by
Inner
Board
Cleared
When
A40215
error
occurs
Cleared
When
A528
error
occurs
Cleared
Written
---
after
transmis-
sion
Cleared
Written
---
after
reception
Cleared
---
---
Cleared
---
---
Cleared
When
---
there is a
normal
response
to the
token
Cleared
See Func-
---
tion col-
umn.
Cleared
When
---
data is
received
525