Auxiliary Area Allocations
Address
Name
Words
Bits
A262
All
Maximum
and
Cycle
A263
Time
A264
All
Present
and
Cycle
A265
Time
A266
All
Program
and
Execution
A267
Time
A268
---
Peripheral
Servicing
Cycle
Time (Sin-
gle CPU
Systems
only)
A270
---
Duplex
Communi-
cations
Cable
A27000
Error
Flags
A27001
A27002
A27003
A27004
A27005
A27006
A27007
A27008
A27009
A27010
A27011
A27012
A27013
A271
---
Duplex
Communi-
cations
Cable Sta-
A27100
tus Flags
A27101
A27102
A27103
A27104
A27105
A27107
512
Function
These words contain the maximum
cycle time since the start of PLC
operation. The cycle time is
recorded in 8-digit hexadecimal with
the leftmost 4 digits in A263 and the
rightmost 4 digits in A262.
With a Single CPU System in Paral-
lel Processing Mode, the maximum
cycle time for instruction execution
will be stored.
These words contain the present
cycle time in 8-digit hexadecimal
with the leftmost 4 digits in A265 and
the rightmost 4 digits in A264.
With a Single CPU System in Paral-
lel Processing Mode, the present
cycle time for instruction execution
will be stored.
These words contain the total time
for program execution with the left-
most 4 digits in A267 and the right-
most 4 digits in A266.
Stores for a Single CPU System
when not in Parallel Processing
Mode.
In Parallel Processing with Synchro-
nous or Asynchronous Memory
Access, this word contains the
peripheral servicing cycle time. The
time is updated every cycle and is
recorded in 16-bit binary.
ON: An error has occurred at some
point in the corresponding I/O Com-
munications Cable.
CPU Rack slot 0 to Expansion Rack
1
CPU Rack slot 1to Expansion Rack
1
Expansion Rack 1 slot 0 to Rack 2
Expansion Rack 1 slot 1 to Rack 2
Expansion Rack 2 slot 0 to Rack 3
Expansion Rack 2 slot 1 to Rack 3
Expansion Rack 3 slot 0 to Rack 4
Expansion Rack 3 slot 1 to Rack 4
Expansion Rack 4 slot 0 to Rack 5
Expansion Rack 4 slot 1 to Rack 5
Expansion Rack 5 slot 0 to Rack 6
Expansion Rack 5 slot 1 to Rack 6
Expansion Rack 6 slot 0 to Rack 7
Expansion Rack 6 slot 1 to Rack 7
Indicate when the corresponding I/O
Communications Cable is duplexed.
(ON when duplexed.)
CPU Rack to Expansion Rack 1
Expansion Rack 1 to Rack 2
Expansion Rack 2 to Rack 3
Expansion Rack 3 to Rack 4
Expansion Rack 4 to Rack 5
Expansion Rack 5 to Rack 6
Expansion Rack 6 to Rack 7
Settings
Status
after
mode
change
0 to FFFFFFFF:
---
0 to
429,496,729.5
ms
(0.1ms units)
0 to FFFFFFFF:
---
0 to
429,496,729.5
ms
00000000 to
---
FFFFFFFF hex
0.0 to
429,496,729.5
ms (0.1-ms
increments)
0 to 4E20 hex,
---
(0.0 to
2,000.0 ms in
units of 0.1 ms)
ON: Duplex
Cleared
Communica-
tions Cable Error
OFF: Normal
ON: Communi-
Cleared
cations Cable
duplexed
OFF: Communi-
cations Cable
not duplexed
Appendix B
Status at
Timing
Related
startup
flags,
settings
---
---
---
---
---
---
---
---
---
---
Each
A40515
cycle
Cleared
When
A271
error
occurs
Cleared
Each
A270
cycle