Flow Of Operation - Omron CP1E CPU UNIT SOFTWARE User Manual

Cp1e cpu unit software
Table of Contents

Advertisement

11-1-2 Flow of Operation

1
2
Create
ladder
program
Precautions for Correct Use
Precautions for Correct Use
A built-in input cannot be used as a normal input, interrupt input, or quick-response input if it is
being used as a high-speed counter input. Refer to 8-3-3 Allocating Built-in Input Terminals for
details.
PLC Setup
Click the Built-in Input Tab and select the Use high speed counter Check Box for high-speed counters
0 to 5. Set the counting mode, reset method, and input setting.
CP1E CPU Unit Software User's Manual(W480)
• Enable the required high-speed counters.
PLC Setup
• Select the Use high speed counter Check Box for high-
• Terminals 00 to 06 on the CIO 0 terminal block can be
• Read the PV from Auxiliary Area or by executing a PRV
Read counter PV
• Execute a PRV instruction.
Read counter frequency
11 High-speed Counters
speed counters 0 to 5. Set the input setting, counting
mode and reset method on the Built-in Input Tab Page of
the PLC Setup using the CX-Programmer.
used for high-speed counters. High-speed counters 0 to
5 correspond to terminals 00 to 06.
instruction.
11
11-3