11 High-speed Counters

11-2 High-speed Counter Inputs

11-2-1 Pulse Input Methods Settings

There are four pulse input methods for high-speed counters.
• Increment pulse input
• Differential phase input (4×)
• Up/Down pulse input
• Pulse+direction input
Increment Pulse Input
The Increment Pulse Input counts signals on a single-phase pulse input. Only incrementing the count is
possible in this mode.
Pulse
0
1
Differential Phase Input (4×)
The Differential Phase Input uses two phase signals (phase A and phase B) and increments/decre-
ments the count according to the status of Differential Phase (4×).
Phase A
Phase B
×4
0
1
Up/Down Pulse Input
The Up/Down Pulse Input uses two signals, an increment pulse and a decrement pulse.
Increment
pulse
Decrement
pulse
11-8
2
3
4
5
6
7
8
2
3
4
5
6
7
8
9
10
11
12
11
10
0
1
2
3
4
5
6
7
9
10
11
12
13
14
15
9
8
7
6
5
4
3
2
1
2
3
4
8
7
6
5
4
3
2
1
CP1E CPU Unit Software User's Manual(W480)
Conditions for Incrementing
the Count
Pulse
Count value
OFF ON
Increment
ON
No change
ON OFF
No change
16
No change
OFF
· Only rising edges are counted.
Conditions for Incrementing/
Decrementing the Count
Phase A Phase B Count value
OFF ON
OFF
Increment
ON
OFF ON
Increment
ON OFF
ON
Increment
ON OFF
OFF
Increment
5
6
7
8
OFF
OFF ON
Decrement
OFF ON ON
Decrement
Decrement
ON
ON OFF
ON OFF
OFF
Decrement
Conditions for Incrementing/
Decrementing the Count
Decrement
Increment
Count value
pulse
pulse
OFF ON
OFF
Decrement
Increment
OFF ON
ON
ON OFF
ON
No change
OFF
ON OFF
No change
0
Increment
OFF
OFF ON
Decrement
OFF ON
ON
No change
ON
ON OFF
ON OFF
OFF
No change
· The count is incremented for each increment
pulse and decremented for each decrement
pulse.
· Only rising edges are counted.