Origin Search Settings
1
Use define origin operation
1-1
Search Direction
1-2
Detection Method
1-3
Search Operation
1-4
Operation Mode
1-5
Origin Input Signal
1-6
Proximity Input Signal
1-7
Search High Speed
1-8
Search Proximity Speed
1-9
Origin Compensation Value
1-10
Origin Search Acceleration Ratio
(Rate)
1-11
Origin Search Deceleration Ratio
(Rate)
1-12
Positioning Monitor Time
CP1E CPU Unit Software User's Manual(W480)
Name
Do not use.
CW
Method 0
Inverse 1
Mode 0
NC
NC
0 pps (disabled)
0 pps (disabled)
0 pps
0 (disabled)
0 (disabled)
0 (ms)
Default
Possible settings
Do not use.
Use.
CW
CCW
Method 0
Method 1
Method 2
Inverse 1
Inverse 2
Mode 0
Mode 1
Mode 2
NC
NO
NC
NO
1 pps
:
100,000 pps
1 pps
:
100,000 pps
-2,147,483,648
:
0
:
+2,147,483,647
1 (pulse/4 ms)
:
65,535 (pulse/4 ms)
1 (pulse/4 ms)
:
65,535 (pulse/4 ms)
0 (ms)
:
9,999 (ms)
7 PLC Setup
When setting is read by
CPU Unit
When power is turned ON
At start of operation
At start of operation
At start of operation
At start of operation
When power is turned ON
At start of operation
At start of operation
At start of operation
At start of operation
At start of operation
At start of operation
At start of operation
7-15
7