Stopping a Pulse Output
Example
Operation
application
Stop pulse
Immediate
output
stop
(Number of
pulses set-
ting is not
preserved.)
Stop pulse
Immediate
output
stop
(Number of
pulses set-
ting is not
preserved.)
Stop sloped
Decelerate
pulse out-
to a stop
put
smoothly.
(Number of
pulses set-
ting is not
preserved.)
CP1E CPU Unit Software User's Manual(W480)
Frequency changes
Pulse frequency
Present
frequency
Time
Execution
Execution
of SPED
of INI
Pulse frequency
Present
frequency
Time
Execution
Execution
of SPED
of SPED
Pulse frequency
Present
Original acceleration/
frequency
deceleration rate
Target
Time
frequency=0
Execution of ACC
Description
Stops the pulse output immedi-
ately and clears the number of
output pulses setting.
Stops the pulse output immedi-
ately and clears the number of
output pulses setting.
Decelerates the pulse output
to a stop.
If ACC started the operation,
the original acceleration/decel-
eration rate will remain in
effect.
If SPED started the operation,
the acceleration/deceleration
rate will be invalid and the
pulse output will stop immedi-
ately.
12 Pulse Outputs
Procedure
Instruction
Settings
PULS
Stop pulse
output
↓
ACC or SPED
(Independent)
↓
INI
PLS2
↓
INI
PULS
• Port
↓
• Indepen-
dent
SPED
• Target fre-
(Independent)
quency = 0
↓
SPED
(Independent)
PULS
• Port
↓
• Indepen-
dent
ACC or SPED
• Target fre-
(Independent)
quency = 0
↓
ACC
(Independent)
PLS2
↓
ACC
(Independent)
12-53