E14 or N14 CPU Units
Termi-
nal
Terminal
block
number
label
CIO 0
00
01
02
03
04
05
06
07
E10 CPU Units
Termi-
nal
Terminal
block
number
label
CIO 0
00
01
02
03
04
05
Note 1 The same pulse inputs must be used for high-speed counter 0 and high-speed counter 1.
2 High-speed counter 2 cannot be used if the input setting of high-speed counter 0 or high-speed counter 1
is set for differential phase inputs (4×), pulse + direction inputs, or up/down pulse inputs.
CP1E CPU Unit Software User's Manual(W480)
Interrupt input settings on Built-in Input Tab
Page
Normal
Interrupt
Interrupt
Normal input
inputs
−
Normal input 0
−
Normal input 1
Normal input 2
Interrupt
input 2
Normal input 3
Interrupt
input 3
Normal input 4
Interrupt
input 4
Normal input 5
Interrupt
input 5
Normal input 6
Interrupt
input 6
Normal input 7
Interrupt
input 7
Interrupt input settings on Built-in Input Tab
Page
Normal
Interrupt
Interrupt
Normal input
inputs
−
Normal input 0
−
Normal input 1
Normal input 2
Interrupt
input 2
Normal input 3
Interrupt
input 3
Normal input 4
Interrupt
input 4
Normal input 5
Interrupt
input 5
8 Overview of Built-in Functions and Allocations
PLC Setup
High-speed counter 0 to 3 settings on Built-
in Input Tab Page
Quick
Quick-
Differential
Increment
response
phase ×4 or
pulse input
inputs
up/down
−
Counter 0,
Counter 0,
increment input
phase A or up
input
−
Counter 1,
Counter 0,
increment input
phase B or
down input
Quick-
Counter 2,
Counter 1,
response
increment input
phase A or up
input 2
input
−
Quick-
Counter 1,
response
phase B or
input 3
down input
Quick-
Counter 3,
Counter 0,
response
increment input
Phase Z or
input 4
reset input
Quick-
Counter 4,
Counter 1,
response
increment input
Phase Z or
input 5
reset input
Quick-
Counter 5,
response
increment input
input 6
−
Quick-
response
input 7
PLC Setup
High-speed counter 0 to 3 settings on Built-
in Input Tab Page
Quick
Quick-
Differential
Increment
response
phase ×4 or
pulse input
inputs
up/down
−
Counter 0,
Counter 0,
increment input
phase A or up
input
−
Counter 1,
Counter 0,
increment input
phase B or
down input
Quick-
Counter 2,
Counter 1,
response
increment input
phase A or up
input 2
input
−
Quick-
Counter 1,
response
phase B or
input 3
down input
Quick-
Counter 3,
Counter 0,
response
increment input
Phase Z or
input 4
reset input
Quick-
Counter 4,
Counter 1,
response
increment input
Phase Z or
input 5
reset input
Origin search set-
tings on Pulse
Output 0/1 Tab
Page
Use
Use
Pulse/direc-
Origin search
tion
Counter 0,
pulse input
Counter 1,
pulse input
Counter 0,
direction
Counter 1,
Pulse 0, Origin
direction
proximity input signal
Counter 0,
reset input
Counter 1,
Pulse 1, Origin
reset input
proximity input signal
−
−
Pulse 0: Origin input
signal
−
−
Pulse 1: Origin input
signal
Use
Pulse/direc-
tion
Counter 0,
pulse input
Counter 1,
pulse input
Counter 0,
direction
Counter 1,
direction
Counter 0,
reset input
Counter 1,
reset input
−
−
−
−
8