Alarms, faults and system messages

10.1 LED

10.1
LED
The converter has a two status LED on the lower edge of the converter casing.
Figure 10-1
Signal states of the LED
The LEDs have different colours and flashing rates to indicate the status of the system in
general, or the status of a specific function.
RDY LED
GREEN - on
GREEN - slow
RED - on
RED - slow
RED - fast
ORANGE - on
SAFE LED
YELLOW - on
YELLOW -
slow
YELLOW - fast
214
LED on the converter casing
Description
There is no fault present
Commissioning or reset to factory settings
General system fault
or
Firmware update is running
Converter is waiting for a power cycled after a firmware update
Fault present - possibly incorrect memory card or unsuccessful firmware update
Converter start-up in progress
Description
One or more safety functions are enabled, but not active or firmware update failed
One or more safety functions are active
or
Converter is waiting for a power cycle after firmware update
The converter has detected a safety function fault and initiated a STOP response
or
Firmware update is running
Operating Instructions, 09/2017, FW V4.7 SP9, A5E34257324B AE