6.4 RESETTING THE 4025TR TO FACTORY DEFAULTS

!
TECHNICAL DESCRIPTION
Pressing SHIFT+CLEAR when the timecode windows are visible sets up
the 4025TR to capture the next EV-COM reset codes.
There are three different methods of resetting the 4025TR to factory
defaults. Under most circumstances the Toolbox method will work fine.
Proceeding with the Factory reset will cause all user configured parameters
including KeyKode head offsets, horizontal char size, user configurations,
etc. to be lost. We recommend that you write down your Head offsets for
PAL and NTSC and that you make a note of the settings shown on your
STATUS screen before proceeding.
6.4.1

Resetting The 4025TR Using The Toolbox Hardware Menu

The FACTORY RESET item of the Toolbox HARDWARE menu is used to
reset
the
4025TR
SHIFT + ENTER when the sub menu screen is displayed to reset the
4025TR to factory defaults.
configuration before returning to the normal operating mode.
6.4.2

Resetting The 4025TR Using The Engineering Shortcut Keys

The 615 and 632 modules may be individually reset to their factory defaults
by using the Engineering shortcut keys. These functions are activated by
pressing the TIME/UB key and the SHIFT key plus the indicated key:
2
3
4
6.4.3

Resetting The 4025TR Using The DIP Switches

The 632 module can be reset to factory defaults by the following
procedure.
1.
Move timecode & edge number displays to bottom of screen.
2.
Unplug the 632 or power down the 4025TR.
3.
Flip the DIP switches to the exact opposite of the current switch
settings.
4.
Push the 632 back in/or power up the 4025TR.
5.
Allow the 4025TR to go through the normal power up displays.
Model 4025TR Film Footage Encoder Manual
to
the
factory
The 4025TR will perform a power-on
Reset 632 (right) board to factory defaults, and reboot
Reset 615 (centre) board to factory defaults, and reboot
Reset all boards to Factory defaults, and reboot
default
parameters.