proper selection of the jumper on the sprocket Pulse card in the telecine
(FY806 or FM735 card).
The FRID pulse is available on pin 17 of the 25 pin External 2 D connector
on the telecine. This pulse should be connected to pin 2 of the Parallel I/O
connector of the 4025TR. Ground for the FRID pulse on pin 18 of the
External 2 connector should be connected to pin 6 of the 4025TR Parallel
I/O connector.
The telecine type item on the Engineering Toolbox Hardware Menu must
be set to QUADRA/FDL. (See section 3.6.4)

2.12.5 Philips QUADRA

The biphase tach pulse is available on the 9 pin D Sepmag connector on
the telecine. Connect pins 1 and 5 from this connector to pins 3 and 7 of
the 9 pin parallel I/O connector of the 4025TR respectively.
Connect
ground (pin 7 on the telecine connector) to pin 6 on the 4025TR connector.
Note that the pulse output should be set to 10 pulses per film frame by
proper selection of the jumper on the sprocket Pulse card in the telecine
(FY806 or FM735 card).
The FRID pulse is available on pin 17 of the 25 pin External 2 D connector
on the telecine. This pulse should be connected to pin 2 pF the Parallel I/O
connector of the 4025TR. Ground for the FRID pulse on pin 18 of the
External 2 connector should be connected to pin 6 of the 4025TR Parallel
I/O connector.
Connect the PRESTOP signal (Pin 3 on the WETGATE connector of the
Quadra) to PIN 4 of the 4025TR PARALLEL connector. You will also need
to remove the cover of the 4025TR and set Jumper J37 on the 7006 I/O
board to the 4IN position.
The telecine type item on the Engineering Toolbox Hardware Menu must
be set to QUADRA/FDL. (See section 3.6.4)

2.12.6 Philips Spirit

The signals required to connect the Spirit telecine are found on the 9 pin D
TC GEN OUT connector (J23) on the Spirit. Connect the biphase tach
pulse outputs (pins 1 and 5) from this connector to pins 3 and 7 of the 9 pin
parallel I/O connector of the 4025TR respectively. Connect ground (pin 7
on the telecine connector) to pin 6 on the 4025TR connector. Note that the
pulse output should be set to 10 pulses per film frame. Connect the Start
of Frame (SOF) pulse (pin 2 on the telecine connector) to pin 2 of the
Parallel I/O connector of the 4025TR.
The telecine type item on the Engineering Toolbox Hardware Menu must
be set to SPIRIT. (See section 3.6.4)
INSTALLATION
Page 2-26