Help Messages; General Messages; Telecine Related Messages - evertz 4025TR Instruction Manual

Film footage encoder
Table of Contents

Advertisement

5.1 615 HELP MESSAGES

SYSTEM DIAGNOSTICS
5.1.1

General Messages

NO NEW PROBLEMS
GENLOCK MISSING
NOVRAM 1ST BIRTHDAY
EVCOM RESET
STACK RESET
HARDWARE/SOFTWARE
MISMATCH
VIDEO STD SWITCH PROBLEM
NOVRAM RETRY COUNT
EXCEEDED
TIC COLLISION
TO: UNEXPECTED INTERRUPT
PLL VIDEO LOCK PROBLEM
INVALID MICROPROCESSOR
5.1.2

Telecine Related Messages

FRAME PULSE MISMATCH @24FPS
FRAME PULSE MISMATCH @1:1
FRAME PULSE MISSING
Model 4025TR Film Footage Encoder Manual
Indicates the 615 message has been reset and no
further problems have been detected.
Video is missing from PGM IN; (GENLOCK LED
on front panel is actually the video reference for
the 613 card).
The Non-volatile memory has been reset to
factory defaults.
An inter-module communications reset occurred,
usually caused by a power on reset of one or all
the cards.
The 615 needed to do some software error
prevention - please call us if you get this
message.
The 615 has detected the firmware is incompatible
with the hardware.
The 615 was unable to switch video standards.
The nonvolatile memory was unable to be
programmed
Please call us if you get this message.
Please call us if you get this message.
The 615 has detected an instability in its Phase
locked loop and cannot lock to the video
reference.
The microprocessor is invalid for the firmware
version.
The incoming FRAME or FRID signal does not
match the selected rate of 24 frames per second.
The incoming FRAME or FRID signal does not
match the selected rate of 30 frames per
second.(NTSC) or 25 frames per second (PAL)
One or more frame pulses was missed. Either the
FRAME/FRID inputs or the PGM VIDEO IN signal
(which triggers the signal sampling) may be at
fault.
Page 5-2

Advertisement

Table of Contents
loading

Table of Contents