Clearing Xds Packets From Memory; Monitoring The Status Of The Parallel Remote Control Inputs; Resetting The Xds Encoder To Factory Defaults; Performing A Front Panel Reset To Its Power-On State - evertz 8083XDS-AD Instruction Manual

Analog and sd-sdi xds encoder
Table of Contents

Advertisement

8083XDS-AD Analog and SD-SDI XDS Encoder
>CLEAR LOCAL XDS
Clear XDS? No
Clear XDS? Yes
>GPI IN MONITOR
Gpi = 80 02 01 02
>TOTAL RESET
Reset = no
Reset = yes
Page 3-20
Select Erase timer off to disable the Erase Timer.

3.3.9 CLEARING XDS PACKETS FROM MEMORY

In the 8084 and 8084AD, local XDS packets are kept in a non-volatile
memory and are restored on power up. XDS packets can only be removed
from memory using the serial port of the encoder, or by using the Clear
Local XDS menu item.
CLEAR LOCAL XDS allows the user to clear the XDS packet memory from
the front panel. Setting this menu item to YES and pressing the
SELECT key will erase the XDS Packet memory. Text articles
will be preserved.

3.3.10 Monitoring the Status of the Parallel Remote Control Inputs

GPI IN MONITOR
is used to monitor the current status of the parallel
remote control inputs. When you press the
display shows something similar to Gpi = 06 02 01 02. The left-
most number is a hexadecimal representation of the bit mapped
parallel input. Bit 0 is the least significant bit, bit 7 is the most
significant bit. (See section 3.5 for a description of the remote
control functions and bit-mappings of the pins).
This display is also used to show the revisions of the factory-
programmed logic devices in the XDS encoder. These are the
other three values shown on the display. Chapter 5 describes
the significance of these values in detail.

3.3.11 Resetting the XDS Encoder to Factory Defaults

TOTAL RESET
is used to reset the configuration items that are
normally saved in non-volatile memory will be restored to the
factory defaults. The serial port buffers and the Article and XDS
queues will be cleared. Articles and XDS packets will also be
removed from memory. When you press the
display shows something similar to Reset = yes. Press the
SELECT keys to reset the XDS encoder. The XDS encoder will
exit the Engineering Setup Menu and the display will show
Reset Done

3.3.12 Performing a Front Panel Reset to its Power-On State

Sometimes it may be desirable to perform a reset of the 8083XDS-AD back
to its power-on, especially if a communications error has left one port
active, which may cause an ACCESS ERROR when another port attempts
to caption. To reset the unit to the power-on state hold down the SHIFT
+ +
keys simultaneously. The 8083XDS-AD will be completely reset to
the values stored in its non-volatile memory and the Article and XDS
queues will be cleared. Articles and XDS packets will not be removed from
memory. The display will show Reset Done.
Revision 1.0.2
or
keys, the
button, the
OPERATION

Advertisement

Table of Contents
loading

Table of Contents