INSTALLATION
This signal may be applied to either of the pair of connectors on the 4025TR
labelled "FILM FRAME". The loop-thru is provided to allow connections to
other devices that may need this signal. This is NOT a video level signal. Do
NOT terminate this signal.
2.11.3 Cintel MKIIIC Digiscan 3
For connection to a Cintel MKIIIC telecine a pre-wired 'Y' interface cable
(Part No WA-651) may be ordered. It permits the 4025TR and the mag
follower to both be connected to the same biphase connections. Figure 7-3
in Chapter 7 shows the correct cable wiring diagram if you decide to wire
the cable yourself.
connector on the Rank, and connect it to the female 12 pin McMurdo
connector end of the WA-615 cable. Connect the male 12 pin McMurdo
end to connector SK24 on the telecine. Connect the 9 pin 'D' connector
end of the cable to the PARALLEL I/O connector on the rear of the
4025TR. On some models of Cintel telecines the polarity of the biphase
signals is reversed. In the event that the 4025TR counts in the reverse
direction when the telecine is in the forward direction, reverse the two
biphase connections to the 4025TR (at the 9 pin 'D" connector).
Remove the coax cable connected to the BSK 43 BNC on the telecine
Digiscan frame, (if any) and connect it to one side of the FILM FRAME loop
on the 4025TR.
connector BSK 43.
Do not terminate this signal.
The telecine type item on the Engineering Toolbox Hardware Menu must
be set to MKIII/DIGI IV. The film frame item on the Engineering Toolbox
Hardware Menu must be set to either LATCHED or SAMPLED.
section 3.6.4 and 3.6.5) In NTSC configurations, the film rate setting on
the FILM drop down menu may be set to Auto, 24 or 30 FPS. (See section
3.4.4 or 3.10.10)

2.11.4 Cintel 4:2:2 Digiscan IV

The Biphase tach pulse is available on a pair of BNC connectors on the
rear of the Mag follower. These biphase signals must be connected to pins
3 & 7 of the 9 pin parallel I/O D connector. Connect ground to pin 6 on the
rear of the 4025TR. Retain the separate shielding of each signal up to the
4025TR in order to prevent cross-coupling which can adversely affect the
biphase reliability.