Selecting How Soon The 4025Tr Detects Loss Of Keykode; Setting The Full Stop Time; Setting The Centering Method - evertz 4025TR Instruction Manual

Film footage encoder
Table of Contents

Advertisement

CHECK DELAY
INFO CHECK
DELAY = 10
$ OR % TO ADJUST
FULL STOP
FULL STOP
TIME = 1:00
$ OR % TO ADJUST
AUTO CENTRE
OFF
ON
OPERATION
mode is set to NEVER, ONCE or PLAY this parameter is
ignored.) See section 3.4.1 of the manual for a description of
the KK JAM ALWAYS mode. The KK SHUTTLE WINDOW sets
how many film frames of difference are allowed between the
KeyKode numbers and the biphase based film edge numbers
(when the telecine is in SHUTTLE).
exceeded the biphase based edge numbers will be updated
from the KeyKode numbers. The factory default setting of 30
means that differences between the KeyKode and biphase
(when the telecine is in SHUTTLE) or more than 30 film frames
will cause a KeyKode jam to occur. Use the $ & % keys to
adjust.
3.7.3

Selecting How Soon the 4025TR Detects Loss of KeyKode

Use the Dropout delay item on the Film tab of the configuration screen to set
the KeyKode Info check delay.
CHECK DELAY
warning in the VCG becomes active when KeyKode is not
present, and the KEYINFO mode is set to INFO CHECK. The
CHECK DELAY WINDOW sets how many feet of film can pass
without reading KeyKode before the INFO CHECK warning in
the VCG is activated. See section 3.4.2 in the manual for a full
description of the INFO CHECK DISPLAY. The factory default
setting of 10 means that ten feet of film without reading
KeyKode will trigger the KeyKode check display of the VCG.
Use the $ & % keys to adjust.
3.7.4

Setting the Full Stop Time

FULL STOP Is used to adjust length of time with no film motion
(measured in seconds and frames) before the 4025TR detects a
Full Stop condition.
when the Full Stop Data packet is sent to a logging computer. It
is also used to determine when the auto centering function will
take place (If auto centering is turned ON). The factory default
setting of 1:00 means that the 4025TR will detect FULL STOP
when the film is stationary for at least 1 second. Use the $ & %
keys to adjust.
3.7.5

Setting the Centering Method

AUTO CENTRE
automatically reframe its biphase counters when the telecine is
Model 4025TR Film Footage Encoder Manual
Is used to adjust how quickly the KEY INFO CHECK
This parameter is used in determining
Is used to select whether the 4025TR will
When this limit is
Page 3-32