5.3
611 HELP MESSAGES
SYSTEM DIAGNOSTICS
5.2.4
Serial Communications Problems
SERIAL: FRAMING/OVERRUN ERR
SERIAL: PARITY ERROR
SERIAL: RECEIVE TIMEOUT 1
SERIAL: RECEIVE TIMEOUT 2
SERIAL: UNIDENTIFIED CMD
DATA LOG EVENT OVERFLOW
5.3.1
General Messages
NO NEW PROBLEMS
GENLOCK MISSING
EVCOM RESET
STACK RESET
INVALID MICROPROCESSOR
5.3.2
Time Code Related Messages
LTC FAILED VALIDATION CHK
VITC FAILED VALIDATION CHK
LTC FAILED FLAGS CHK
VITC FAILED FLAGS CHK
LTC FAILED COMPARE CHK
VITC FAILED COMPARE CHK
LTC FAILED WINDOW CHK
VITC FAILED WINDOW CHK
LTC FAILED DATA PARITY CHK
VITC FAILED DATA PARITY CHK
Model 4025TR Film Footage Encoder Manual
Indicate problems with the serial input data from
the computer running the KeyLog TRACKER™
software. These include parity/baud problems
and message format problems.
Indicates that a data log packet was lost because
of serial overflow conditions.
Indicates the 611 message has been reset and
no further problems detected.
The VITC RDR IN video input is missing or
disturbed.
An inter-module communications reset
occurred, usually caused by a power on reset of
one or all the cards.
The 611 needed to do some software error
prevention - please call us if you get this
message.
The microprocessor is invalid for the firmware
version.
The incoming timecode was rejected because
the time contained illegal numbers such as hours
> 24, minutes > 60, etc.
The incoming timecode was rejected because
the normally static timecode flags (drop frame,
colour frame, binary group, etc.) had changed.
The incoming timecode was rejected because it
differed too much from the previous timecode
input.
The incoming timecode was rejected because it
differed too much from the previous valid
timecode.
The incoming timecode was rejected because
the parity checks failed (this is a special mode,
not normally available).
Page 5-7