Viewing The Firmware Version; Upgrading The Firmware; Resetting The Hd9010-Sie To Its Factory Defaults; Configuring The General Purpose Inputs And Outputs - evertz HD9010-SIE Instruction Manual

Hdtv source id encoder
Table of Contents

Advertisement

3.8.9. Viewing the Firmware Version

FIRMWARE VERSION
1.1 build 66

3.8.10. Upgrading the Firmware

FIRMWARE UPGRADE
Upgrade
No
Yes

3.8.11. Resetting the HD9010-SIE to its Factory Defaults

FACTORY RESET
Reset
No
Yes
3.9.

CONFIGURING THE GENERAL PURPOSE INPUTS AND OUTPUTS

A 9 pin D connector located on the rear panel labelled PARALLEL I/O provides control inputs for
remote control of some of the model HD9010-SIE functions. Several of these inputs can also be
configured as open collector outputs that can be assigned to a variety of functions. The pinout of the D
connector is shown in Table 2-1. For information about changing the default functions of the GPI inputs
contact the factory.
The GPI front panel display (accessible by pressing the DISPLAY button one or more times) will show
the status of the GPI inputs. The GPI status display (GPI: 11111111 ) is a group of 8 digits
representing the GPI inputs (GPI 8 on the left, GPI 1 on the right) When the digit is showing a 0, the
GPI input is low. When the digit is showing a 1 the input is high.
There are eight remote control inputs as shown in Table 3-5.
OPERATION
HD9010-SIE High Definition Source ID Encoder Manual
The Firmware Version menu item allows you to view the firmware
version that is installed in the HD9010-SIE.
SELECT key, the display shows the software version which will be
something like:
1.1 build 66
The Firmware Upgrade menu item allows you to initiate an upgrade of
the firmware from the front panel. When you press the SELECT key,
you are prompted to confirm that you really want to upgrade. Turn the
shaft encoder knob to yes and then press the SELECT key to confirm.
When you press the SELECT key the unit will be placed in
programming mode and its serial port is opened to communicate with
the terminal software program.
See section 5.2 for complete instructions on
UPGRADING....

upgrading the firmware.

The Factory Reset menu item allows you to reset the HD9010-SIE to its
factory default condition. When you press the SELECT key, you are
prompted to confirm that you really want to reset the unit. Turn the
shaft encoder knob to yes and then press the SELECT key to confirm.
When you press the SELECT key the unit will be reset to its factory
default condition. The front panel display shows RESETTING...
Revision 1.2
When you press the
The front panel display shows
Page 3-11