VLT® Servo Drive System ISD 511
Operating Guide
-
Constants for parsing problems of a CAM.
-
Error reason is returned by function block MC_CamTableSelect_DDS.
•
DDS_FB_ErrorConstants
-
Constants for errors inside POUs.
-
The reason is given in an output ErrorInfo.ErrorID that is available in all POUs.
•
DDS_Intern
-
Constants which are needed internally for the library.
-
They are not intended to be used in an application.
•
DDS_LabCam
-
Constants for the creation of labeling CAMs.
•
DDS_SdoAbortCodes
-
Constants for errors concerning reading and writing of parameters.
-
The reason is given in an output AbortCode that is available in several POUs.
•
PSM_ErrorCodes
-
Constants for error codes of the Power Supply Module (PSM 510).
-
Error codes can be read using the function block DD_ReadPsmError_PSM and/or DD_ReadPsmWarning_PSM.
•
PSM_TraceSignals
-
Constants for the trace signals of the Power Supply Module (PSM 510).
-
Intended to be used with the function block DD_Trace_PSM.
•
DAM_ErrorCodes
-
Constants for error codes of the Decentral Access Module (DAM 510).
-
Error codes can be read using the function block DD_ReadDamError_DAM and/or DD_ReadDamWarning_DAM.
•
DAM_TraceSignals
-
Constants for the trace signals of the Decentral Access Module (DAM 510).
-
Intended to be used with the function block DD_Trace_DAM.
•
ACM_ErrorCodes
-
Constants for error codes of the Auxiliary Capacitors Module (ACM 510).
-
Error codes can be read using the function block DD_ReadAcmError_ACM and/or DD_ReadAcmWarning_ACM.
•
ACM_TraceSignals
-
Constants for the trace signals of the Auxiliary Capacitors Module (ACM 510).
-
Intended to be used with the function block DD_Trace_ACM.
6.5.5 Instantiating AXIS_REF_DDS in Automation Studio™
Procedure
1.
Create 1 instance of function block AXIS_REF_DDS (located in folder DDS_Drive) for every servo drive that has to be control-
led or monitored.
2.
To create a link to the physical servo drive, link each instance of AXIS_REF_DDS to 1 physical servo drive. This makes it the
logical representation of 1 physical servo drive.
-
Open the Logical View.
-
Initialize each instance with its node number and the slot name it is connected to (for example, IF3).
-
Initialize each instance of a drive with its DriveType.
Danfoss A/S © 2023.08
Commissioning
AQ377148425069en-000101 / 130R1213 | 71