VLT® Servo Drive System ISD 511
Operating Guide
Possible causes
•
Phase-to-phase short.
•
Short on backlink.
•
Short on hybrid cable.
•
Short on EXM 510 connector or cable.
•
Short on ISD 511 connector.
Troubleshooting
•
Check the cabling
•
Check for loose connections.
9.3.3 DC-link Voltage Too Low (Error 0x3220/0x104)
This fault applies to all system modules.
Possible cause
•
Incorrect mains input supply.
Troubleshooting
•
Check that the supply voltage matches the allowed specification.
9.3.4 Current Overload Trip (Error 0x2396/0x15C)
This fault applies to the PSM 510 and the DAM 510.
Possible causes
•
The sum of the servo drive current exceeds the maximum rating of the DAM 510.
•
The sum of the system modules' current exceeds the maximum rating of the PSM 510.
•
Short on backlink.
Troubleshooting
•
Check the servo drive current consumption.
•
Avoid simultaneous acceleration of all servo drives.
•
Decrease the acceleration value.
9.3.5 High Cont. Power Overload (Error 0x2313/0x161)
This fault applies to the PSM 510.
Possible causes
•
The PSM 510 was operating at over 140% of the nominal power rating for too long.
Troubleshooting
•
Check the current consumption.
9.3.6 Continuous Power Overload (Error 0x2314/0x162)
This fault applies to the PSM 510.
Possible causes
•
The PSM 510 was operating at 100–140% of the nominal power rating for too long.
Troubleshooting
•
Check the current consumption.
9.3.7 AUX Overcurrent (Error 0x2391/0x125)
This fault applies to the DAM 510.
Possible causes
•
The servo drives are consuming more power on the U
Troubleshooting
•
Ensure that the number of servo drives on 1 line does not exceed 68.
Danfoss A/S © 2023.08
line than allowed.
AUX
Diagnostics
AQ377148425069en-000101 / 130R1213 | 99