VLT® Servo Drive System ISD 511
Operating Guide
Table 97: Firmware: Power cycle needed (0xFF71 / 0x11C)
Code
PROFINET
Name
®
code
0xFF71
0x11C
Firmware: Pow-
er cycle needed
9.4.72 Firmware: Update started (0xFF72 / 0x11D)
This error is valid for PSM 510, DAM 510, ACM 510, and ISD 511.
Table 98: Firmware: Update started (0xFF72 / 0x11D)
Code
PROFINET
Name
®
code
0xFF72
0x11D
Firmware: Up-
date started
9.4.73 Firmware: Update invalid (0xFF73 / 0x15B)
This error is valid for PSM 510 and DAM 510.
Table 99: Firmware: Update invalid (0xFF73 / 0x15B)
Code
PROFINET
Name
®
code
0xFF73
0x15B
Firmware: Up-
date invalid
9.4.74 STO active while drive enabled (0xFF80 / 0x11E)
This error is valid for ISD 511.
Table 100: STO active while drive enabled (0xFF80 / 0x11E)
Code
PROFINET
®
code
0xFF80
0x11E
9.4.75 STO mismatch (0xFF81 / 0x11F)
This error is valid for ISD 511.
Table 101: STO mismatch (0xFF81 / 0x11F)
Code
PROFINET
code
®
0xFF81
0x11F
9.4.76 P_STO error (0xFF85 / 0x120)
This error is valid for ISD 511.
Danfoss A/S © 2023.08
Severity (warning/
error/trip lock)
Warning, error
Severity (warning/
error/trip lock)
Warning, error
Severity (warning/
error/trip lock)
Error
Name
Severity (warning/
error/trip lock)
STO active while
Error
drive enabled
Name
Severity (warning/error/
trip lock)
STO mis-
Trip lock
match
Description
The firmware update transfer is completed
but a power cycle is required before the
new firmware is active.
Description
Firmware update is in progress.
Warning changes to error when an attempt is
made to enable the device in this state.
Description
Invalid or corrupted firmware package
update.
Last valid firmware package has been loa-
ded.
Description
STO activated while drive was enabled
or tried to enable while STO active.
Description
Dual diagnosis of STO voltage not
plausible.
AQ377148425069en-000101 / 130R1213 | 115
Diagnostics
LCP name
need power-
cycle
LCP name
FW update
LCP name
FW upd invalid
LCP name
STO active
LCP name
STO mismatch
Need help?
Do you have a question about the VLT ISD 511 and is the answer not in the manual?