Specifications
Cooling
Mounting
Weight
11.2.2 Characteristic Data for Power Supply Module (PSM 510)
Table 111: Characteristic Data for PSM 510
Definition
Input
Mains input voltage
Input current @ U
MIN
Input power
U
input voltage
AUX
U
current consumption at 24 V DC
AUX
U
current consumption at 48 V DC
AUX
Output
DC-link voltage
DC-link capacitance
Rated current I
N
Rated power P
N
Peak power P
t <3.0 s)
max
Internal brake resistor
(1)
Peak power P
max
Rated power P
N
Nominal resistance
External brake resistor
Peak power P
max
Rated power P
N
Minimum resistance
General
Protective measures
Line filter in accordance with EN 61800-3
Cooling
Danfoss A/S © 2023.08
Unit
Typical value
Via flange and natural convection
Via flange
kg [lb]
4.2 [9.26]
Unit
Power size 1
V AC
400–480 ±10%, 3-phase (see
A
VA
V DC
A DC
A DC
V DC
µF
A
kW
kW
kW
W
kW
kW
Power size 2
5.2 Electrical Environmental
20
34
12.5
22
24/48 ±10%
2.0
1.0
565–680 ±10%
1800
20
40
10
20
20
40
8
150
15
60
7.5
10
Overload, short-circuit, and ground fault protection
Category C3
Integrated fan
AQ377148425069en-000101 / 130R1213 | 129
Specifications
Condition
Power size 3
Conditions)
50
32
60
30
60