Overcurrent Short Circuit (0X2320 / 0X163); Ground Fault (0X2330 / 0X151); Aux Overcurrent (0X2391 / 0X125); Aux User Limit Current (0X2393 / 0X127) - Danfoss VLT ISD 511 Operating Manual

Table of Contents

Advertisement

VLT® Servo Drive System ISD 511
Operating Guide
Table 30: Continuous power overload (0x2314 / 0x162)
Code
PROFINET
code
®
0x2314
0x162

9.4.5 Overcurrent short circuit (0x2320 / 0x163)

This error is valid for PSM 510 and DAM 510.
Table 31: Overcurrent short circuit (0x2320 / 0x163)
Code
PROFINET
code
®
0x2320
0x163

9.4.6 Ground fault (0x2330 / 0x151)

This error is valid for PSM 510, DAM 510, and ISD 511.
Table 32: Ground fault (0x2330 / 0x151)
Code
PROFINET
code
®
0x2330
0x151

9.4.7 AUX overcurrent (0x2391 / 0x125)

This error is valid for DAM 510.
Table 33: AUX overcurr (0x2391 / 0x125)
Code
PROFINET
®
code
0x2391
0x125

9.4.8 AUX user limit current (0x2393 / 0x127)

This error is valid for DAM 510.
Table 34: AUX user limit current (0x2393 / 0x127)
Code
PROFINET
®
code
0x2393
0x127

9.4.9 AUX user limit current warning (0x2394 / 0x128)

This error is valid for PSM 510 and DAM 510.
102 | Danfoss A/S © 2023.08
Name
Severity (warning/error/trip
lock)
Continuous power
Warning, error
overload
Name
Severity (warning/error/trip
lock)
Overcurrent short
Trip lock
circuit
Name
Severity (warning/error/trip
lock)
Ground fault
Warning, error
Name
Severity (warning/error/
trip lock)
AUX overcur-
Error
rent
Name
Severity (warning/
error/trip lock)
AUX user limit
Error
current
Description
Continuous power over-
load error.
Description
Overcurrent short circuit er-
ror.
Description
Discharge from output phases
to ground.
Description
Current on the AUX line has reached
the overcurrent limit.
Description
Current on the AUX line has reached
the user-defined limit for fault.
AQ377148425069en-000101 / 130R1213
Diagnostics
LCP name
cont pwr ovld
LCP name
over curr short
LCP name
ground fault
LCP name
AUX overcurr
LCP name
AUX curr limit