Danfoss VLT ISD 511 Operating Manual page 109

Table of Contents

Advertisement

VLT® Servo Drive System ISD 511
Operating Guide
Table 65: Output phase U failure (0x5412 / 0x124)
Code
PROFINET
Name
®
code
0x5412
0x124
Output phase
V failure
9.4.40 Output phase W failure (0x5413 / 0x125)
This error is valid for ISD 511.
Table 66: Output phase U failure (0x5413 / 0x125)
Code
PROFINET
Name
®
code
0x5413
0x125
Output phase
W failure
9.4.41 EE Checksum Error (parameter missing) (0x5530 / 0x10A)
This error is valid for ISD 511.
Table 67: EE Checksum Error (parameter missing) (0x5530 / 0x10A)
Code
PROFINET
®
code
0x5530
0x10A
9.4.42 Parameter error (0x6320 / 0x10B)
This error is valid for PSM 510, DAM 510, ACM 510, and ISD 511.
Table 68: Param err (0x6320 / 0x10B)
Code
PROFINET
code
®
0x6320
0x10B
9.4.43 Conf par ver (0x6382 / 0x15D)
This error is valid for PSM 510, DAM 510, ACM 510, and ISD 511.
Table 69: Configuration parameters version error (0x6382 / 0x15D)
Code
PROFINET
Name
®
code
0x6382
0x15D
Configuration
parameters ver-
sion error
9.4.44 Configuration parameters limits error (0x6383 / 0x164)
This error is valid for PSM 510, DAM 510, and ACM 510.
Danfoss A/S © 2023.08
Severity (warning/
error/trip lock)
Error
Severity (warning/
error/trip lock)
Error
Name
Severity (warning/
error/trip lock)
EE Checksum Error (pa-
Trip lock
rameter missing)
Name
Severity (warning/error/trip
lock)
Parameter error
Trip lock
Severity (warn-
ing/error/trip
lock)
Trip lock
Description
Calibration of current measurement on output
phase V not successful (an excessive offset is
present). Contact Danfoss.
Description
Calibration of current measurement on output
phase W not successful (an excessive offset is
present). Contact Danfoss.
Description
EEPROM checksum error or missing
device parameter. Contact Danfoss.
Description
A parameter has an invalid value.
Description
Configuration parameter set version mismatch: pa-
rameter set is not valid for this device.
Check the configuration file sent to the device and re-
place it. If the error persists, contact Danfoss.
AQ377148425069en-000101 / 130R1213 | 109
Diagnostics
LCP name
Output
phase V
LCP name
Output
phase W
LCP name
eeprom err
LCP name
param err
LCP
name
conf par
ver

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the VLT ISD 511 and is the answer not in the manual?

Table of Contents