VLT® Servo Drive System ISD 511
Operating Guide
Illustration 81: U
Connector
AUX
Table 121: Pin Assignment of U
Descrip-
Notes
Pins
tion
(left to
right)
1
24 V AUX
Used for 24–48 V DC input to
the Power Supply Module
2
GND
(PSM 510).
-
Only PELV potential can be connected to the U
POSSIBLE LOSS OF FUNCTIONAL SAFETY PROTECTION
The functional safety feature may be affected if the U
-
Ensure that the U
input remains below 60 V.
AUX
11.6.5.1 24/48 V Cable Cross-Sections for PSM 510
Minimum cable cross-section for CE (minimum 70 °C, Cu)
Minimum cable cross-section for UL (minimum 60 °C, Cu)
11.6.6 LCP Connector (M8, 6-pole)
There is an LCP connector on the front of all the system modules. It is used to connect the LCP directly via a cable.
4
3
6
5
2
1
Illustration 82: LCP Connector (M8, 6 pole)
Danfoss A/S © 2023.08
Connector
AUX
N O T I C E
input.
AUX
C A U T I O N
AUX
Rating/parameter
Nominal input voltage: 24 V/48 V DC ±10%
Maximum current: 50 A
Maximum cross-section: 16 mm
Maximum cable length: 3 m
Conductor cross-section range 0.75–16 mm
AWG 4)
input exceeds 60 V.
Specifications
2
2
, solid or flexible (AWG 18–
16 mm
4 AWG
AQ377148425069en-000101 / 130R1213 | 139
2