10.8 Fan Replacement
Illustration 63: Fan Replacement on 100 mm Modules
-
See the VLT® Servo Drive System ISD 510, DSD 510, MSD 510 (VLT® Flexmotion
fan types.
Procedure
1.
Use a screwdriver as a lever to release the fan holder.
2.
Remove the fan.
3.
Replace the fan with an identical type fan.
10.9 Product Returns
Danfoss products can be returned for disposal at no charge. A prerequisite for this is that they are free of deposits, such as oil,
grease, or other types of contamination that hampers disposal. Furthermore, foreign materials or third-party components cannot be
included with the returned product.
Ship the products free on board to the local Danfoss sales company.
10.10 Recycling
Take metals and plastics to recycling stations.
The servo drives and system modules are classified as electronic waste, and the packaging is classified as packaging waste.
10.11 Disposal
Devices containing electronic components cannot be disposed of as normal domestic waste.
Dispose of the servo drives and system modules as hazardous waste, electrical waste, recyclable waste, and so on, in accordance
with applicable local regulations.
124 | Danfoss A/S © 2023.08
N O T I C E
Maintenance, Decommissioning
) Design Guide for further information on
AQ377148425069en-000101 / 130R1213