Chapter 4 - System Installation

24 VDC to Robot

This section covers the cable that connects the 24 VDC power supply to the robot.
24 VDC Mating Connector
The 24 VDC mating connector and two pins are supplied with each system. They are
shipped in the Accessory Kit.
Connector Details
Ground
24 VDC
Pin Details
Recommended crimping tool: Molex Hand
Crimper
Creating 24 VDC Cable
1. Locate the connector and pins from the preceding table.
2. Use 14-16 AWG wire to create the 24 VDC cable. Select the wire length to safely
reach from the user-supplied 24 VDC power supply to the robot base.
3. Crimp the pins onto the wires using the crimping tool recommended in the
preceding table.
4. Insert the pins into the connector. Confirm that the 24 V and ground wires are in
the correct terminals in the plug.
5. Prepare the opposite end of the cable for connection to your user-supplied 24
VDC power supply.
Installing 24 VDC Robot Cable
1. Connect one end of the shielded 24 VDC cable to your user-supplied 24 VDC
power supply. See
ground on the power supply. Do not turn on the 24 VDC power until instructed
to do so in
2. Plug the mating connector end of the 24 VDC cable into the 24 VDC connector on
the interface panel on the back of the robot. The cable shield should be connected
to the ground point on the interface panel.
48
Adept Cobra i600/i800 Robot User's Guide, Rev E
Table 4-3. 24 VDC Mating Connector Specs
Figure
4-7. The cable shield should be connected to frame
Chapter
6.
Connector receptacle, 2 position, type:
Molex Sabre, 18 A, 2-Pin
Molex P/N 44441-2002
Digi-Key P/N WM18463-ND
Adept P/N 02708-000
Molex connector crimp terminal,
female, 14-18 AWG
Molex P/N 43375-0001
Digi-Key P/N WM18493-ND
Adept P/N 02709-000
Molex P/N 63811-0400
Digi-Key P/N WM9907-ND